Table 7. Configuration Headers and Jumpers (Continued)

24

 

 

Related Headers,

Header

Function

Registers or Devices

J11

SocketModem Power

 

 

(3 V DC/5 V DC)

 

 

 

 

J12

RS-485_1_EN

 

 

 

 

J13

RS-485_2_EN

 

 

 

 

J14

RT_1

 

 

 

 

J15

RT_2

 

 

 

 

Table 8 through Table 13 list jumper information concerning the shunt status, functions, and devices affected of selected jumpers.

Table 8. J6.9–J6.11-Modem Enable/Disable

Shunt Status Function

Device Affected

IN

Modem connector (P2) is

UART1 cannot communicate through P2.

 

disabled

Ports D and F can be assigned to functions

 

 

other than UART1.

OUT

Modem connector (P2) is

If the embedded SocketModem is not in the

 

enabled

socket, UART1 communicates through P2.

Table 9. J6.12–J6.14-Console Enable/Disable

Shunt

 

 

Status

Function

Device Affected

IN

Console connector (P1) is disabled

If J6.12–14 is IN and J10 is IN, Port A

 

 

(3-5) is assigned to IrDA; if J10 is

 

 

OUT Port A (3-5) is assigned to

 

 

UART0.

 

 

 

OUT

Console connector (P1) is enabled

None

 

 

 