Z8 Encore!® Flash Microcontroller Development Kit

User Manual

Table 10. J7 External Vref

25

Shunt Status Function

Device or Register Affected

IN

External Vref is used for ADC

Internal Vref is disabled.

OUT

Internal Vref is used for ADC

Internal Vref is enabled.

Table 11. J9 Vref

 

Function

Device or Register Affected

J9-1

Test point to external Vref

Vref

 

 

 

J9-2

GND

None

 

 

 

Table 12. J10 IrDA Enable/Disable

Shunt Status

Function

Device Affected

IN

IrDA enabled

Only the IrDA interface is operational.

 

 

 

OUT

IrDA disabled

UART0 communicates through RS-232.

 

 

If J6 12-14 is IN Port A (3-5) can be

 

 

assigned to other functions (console

 

 

connector P1 is disabled).

 

 

If J6 12-14 is OUT console connector P1

 

 

is enabled (Port A (3-5) is assigned to

 

 

UART0).

 

 

 

Note: If the IrDA board is installed the Console port is disabled.