Table 13. J11 SocketModem Power (3 V DC/5 V DC)

26

Shunt Position

Function

Device Affected

IN (pins 1-2)

5.0 V DC is provided to power

SocketModem

 

SocketModem

 

OUT (pins 2-3)

3.3 V DC is provided to power

SocketModem

 

SocketModem

 

Table 14. J12–RS-485_1_Enable First Interface

Shunt Position

Function

Device Affected

IN

RS-485 disabled

none

 

 

 

OUT

Enables RS-485 first interface

Console and IrDA

 

 

 

Table 15. J13–RS-485_1_Enable Second Interface

Shunt Position

Function

Device Affected

IN

RS-485 disabled

none

 

 

 

OUT

Enables RS-485 second interface

SocketModem

 

 

 

Table 16. J14–RT_1, Termination Resistors Enable, RS-485 First Interface

Shunt Position

Function

Device Affected

IN

First RS-485 interface termination resistors

none

 

disabled

 

OUT

Enables first RS-485 interface termination

none

 

resistors

 