CARBON MONOXIDE SPECIFICATIONS

Range:

0 to 500 ppm (for CO 500)

0 to 999 ppm (for CO 999) Response Time:

T90 < 25 seconds Operating Temperature Range:

-20 to +50 oC (-4 to +122 o F)

Graphic Display Temperature Range: -10 to +60 oC

(+14 to +140 oF)

Operating Humidity:

15 to 90% RH, Non-Condensing Recommended Storage Temperature:

0to 20 oC (32 to 68 oF)

Sensor Accuracy:

±3% of Applied Gas

Linearity:

±3% of Full Scale

Battery Life:

About 100 Hours - Non-Alarming About 800 Hours in Battery Save Mode

Sensor Cross Sensitivity:

Filtered against H2S, 15 ppm: < 0.5 ppm Filtered against SO2, 5 ppm 0 ppm Nitric Oxide, 35 ppm: < 3 ppm Nitrogen Dioxide, 5 ppm: - 1 ppm Chlorine, 1 ppm 0 ppm

Hydrogen, 100 ppm: < 40 ppm

Ethylene, 100 ppm: < 50 ppm

Ethanol, 200 ppm: 0 ppm

Consult Factory for additional information.