ATM Port Redundancy Configuration Screen
Local Management 3-35
3. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press
ENTER. The changes are saved to memory.
3.10.6 Setting the Periodic Test Status Field
To enable or disable the Periodic test status feature, perform the following steps:
1. Use the arrow keys to highlight the Periodic test status field.
2. Press the SPACE bar to toggle between the choices until the appropriate mode displays
(Enabled or Disabled).
3. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press
ENTER. The changes are saved to memory.
3.10.7 Setting the Periodic Test Time
To change the Periodic test time field from the default value of 01:00.00 (1:00 A.M.), perform the
following steps:
1. Use the arrow keys to highlight the Periodic test time field.
2. Enter the time in this format: HH:MM.SS
3. Press ENTER to set the test time entered in the Periodic test time field.
4. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press
ENTER.
5. If the time entered is a valid format, the Event Message Line at the top of the screen displays
“SAVED OK”. If the entry is not valid, Local Management does not alter the current valu e and
refreshes the Periodic test time field with the p re vious value.
NOTE: If the Revert to Primary port field is set to Manual, the pr imary port must be
re-activated by the user via Local/Remote Management.
NOTE: When entering the time in the Periodic test time field, separators between
hours, minutes, and seconds must be added. For example, to set the Periodic test time
to 12:00 P.M. (Noon), type “12:00.00” in the Periodic test time field.