Enterasys Networks VHSIM2-A6DP manual Mode Toggle, Status Toggle

Models: VHSIM2-A6DP

1 118
Download 118 pages 61.27 Kb
Page 99
Image 99

Discovery ELAN Setup Screen

Figure 3-21 ATM Discovery ELAN Setup Screen

Index ELAN Name

Mode

Status

1

Master

Enabled

2

Master

Disabled

3

Master

Disabled

4

Master

Disabled

5

Master

Disabled

6

Master

Disabled

SAVE

PREV

NEXT

EXIT

RETURN

2825_24

The following definitions describe each of the ATM Discovery ELAN Setup screen fields:

Index (Read-only)

Displays the number assigned to this ELAN. A total of 16 discovery ELANs can be assigned to the VHSIM2-A6DP.

ELAN Name (Modifiable)

Used to enter the name of the discovery ELAN that the VHSIM2-A6DP will join when the discovery ELAN becomes enabled.

Mode (Toggle)

Used to toggle between “Master” and “Slave”. When the VHSIM2-A6DP is configured to be in “Master” mode, it will accept connections from all other VHSIM2-A6DPs in the Discovery ELANs it belongs to. When the VHSIM2-A6DP is configured to be in “Slave” mode, it will only accept connections from other VHSIM2-A6DPs configured to be in “Master” mode.

Status (Toggle)

Used to toggle between Enabled and Disabled. The Status field is used to direct the VHSIM2-A6DP to either join the specified discovery ELAN (Enabled), or disconnect from the specified discovery ELAN (Disabled).

Local Management 3-65

Page 99
Image 99
Enterasys Networks VHSIM2-A6DP manual Mode Toggle, Status Toggle