GAS LINE CONNECTION

Initial Installation

GAS LINE CONNECTION AND TESTING:

WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

GAS LINE CONNECTION

This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in a 3⁄8” male NPT fitting. Consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in Canada, or in the USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223.1.

The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.

The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1⁄2 PSIG (3.45 KPa) or damage will occur to the valve.

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1⁄2 psig (3.45 KPa).

Always check for gas leaks with a soap and water solution after completing the required pressure test.

 

 

��������

 

�����

 

 

 

�������� ���

 

 

�������� ���

 

 

 

 

 

TP TH

 

OUT

IN

 

 

 

 

 

TP

H

O

 

 

I

L

OF

 

 

 

 

 

 

 

F

 

 

 

 

P

TH

 

 

I

 

 

L

 

 

T

O

 

 

 

 

 

 

NO

 

T

P

 

 

 

I

 

 

 

OL

 

 

 

 

����� ����������

������

 

��� �������

�����

����

 

����

Figure 28: Fully Labeled Gas Valve.

TO TEST VALVE PRESSURES

The pressure taps are located on the left side of the valve

Turn set screw 1 turn counter clockwise to loosen,

Place 5/16” (8 mm) I.D. hose over pressure tap system.

Check pressures using a manometer.

When finished, release pressure, remove hose & tighten set screw.

Table 5: Pressure and BTU Information.

 

Natural Gas

Propane

Main Burner

#48 DMS

#57 DMS

 

 

 

Manifold Pressure

3.8” W.C. / 0.95KPa

11.0” W.C. / 2.7KPa

 

 

 

Min. Manifold Pressure

1.1” W.C. / 0.27KPa

2.7” W.C. / 0.67KPa

 

 

 

Max Supply Pressure

7.0” W.C. / 1.74KPa

13.0” W.C. / 3.28KPa

 

 

 

Min. Supply Pressure

5” W.C. / 1.24KPa

12.0” W.C. / 2.98KPa

 

 

 

Max BTU/hr Input

17,000 BTU/hr / 4.98KW

16,000 BTU/hr / 4.68KW

 

 

 

Min. BTU/hr Input

10,000 BTU/hr / 2.93KW

8,000 BTU/hr / 2.34KW

NEVER USE AN OPEN FLAME FOR LEAK TESTING.