MAIN BURNERS WILL NOT LIGHT CON’T.

Check spill switch operation

on B-vented models only SEE PAGE 10 FIGURE 9.

Check the “ON-OFF” switch and thermostat for proper operation.

Make sure that the main burner orifices are not clogged or damaged.

Bypass spill switch with a jumper wire as shown. If the unit starts, replace the spill switch. DO NOT LEAVE BY PASSED IN.

Use a jumper wire. If the unit

starts, replace switch if

necessary.

Remove the top tray.

Remove orifice and clean.

Replace if damaged.

 

 

 

 

 

 