Turn the switch to the “ON” position; check the millivolt readings at the thermopile make sure that the readings meet manufacters specifications. Turn the unit “OFF”.

Install a manometer on the inlet side of the gas valve marked (E), re light the appliance make sure that the inlet pressure meets the manufactures specifications.

Shut the unit “OFF” once again and do an outlet (manifold) pressure test. Relight the appliance and make sure the outlet (manifold) pressure is within manufactures specifications.

FINALLY, check to make sure that the unit is venting properly by placing a match in the dilution air outlet or in the draft tube on insert models. If the match is blown out then there is some sort of restriction. Correct if necessary.

CLEANING THE APPLIANCE

Only use a very soft cloth an a non abrasive cleaner, DO NOT use any alcohol’s, mineral spirits, gasoline’s or abrasive cleaners.

When cleaning the glass there could be some stubborn material left on the glass, DO NOT use a scraper or abrasive cleaning agents on the glass because this could scratch the glass which in turn will make he glass weak at the point of the scratch. There is a glass cleaner that is specially designed for gas fireplaces, which can be purchased at your local dealer.

 

 

 

 

 

 