6)FLAME LIFTING

A)B-VENTED MODELS

Check air shutter on the

burner tube (venturi).

Make sure there are no

leaks in the venting system.

Improper venting

configuration.

Make sure that manifold

(outlet).

Pressure is correct.

Adjust air shutter, by

closing shutter.

DO NOT GO TOO FAR OR

THE UNIT WILL SOOT.

Seal venting if necessary.

Correct if necessary.

Use a manometer to check

gas pressure.

SEE PAGE 5 FIGURE 7.

 

 

 

 

 

 

Sherwood Industries Ltd.

ENVIRO

PAGE 17

 

 

 

 

 

 