B) DIRECT VENT MODELS

Check air shutter on the

burner tube (venturi).

Make sure there are no leaks

in the venting system.

Make sure the unit is not recirculating flue products.

Make sure the gas pressure is correct for fuel being used.

Make sure the orifice size is the same as the rating plate.

Add a vent restrictor ring.

SEE OWNERS MANUAL.

Adjust air shutter.

Close until flame sits onto

the burner ports.

Seal exhaust tube with high

temperature silicone. Also make sure that combustion air pipe is sealed.

Check flue for blockage or

high wind situations.

Use a manometer to check

gas outlet (manifold)

pressure.

SEE PAGE 5 FIGURE 7.

Correct if necessary.

Only if necessary.

 

 

 

 

 

 