5) SOOTING

Make sure log placement is

in the correct location.

Make sure there is sufficient

air supply.

Check air shutter on the venturi tube for proper primary air adjustment.

SEE PAGE 16.

Make sure orifice matches

that on the rating plate.

Make sure outlet (manifold)

pressure is correct.

Make sure the unit has been

derated for high altitude

applications. (if required)

Check to make sure that the

vent is drafting properly.

Correct to manufactures

specifications.

Correct if necessary.

Outside air supply may be

required on B-vented

models.

Increase primary air.

Open air shutter.

Correct if necessary.

Use a manometer to check

the gas pressure.

SEE PAGE 5 FIGURE 7.

Correct if necessary.

Correct if necessary.

 

 

 

 

 

 