Secondary Installation

Installation of Optional Blower:

1. Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage

Control panel (Fan control location)

Screw hole

Valve cover

Fan assembly

Figure 53: Optional Blower (Fan) Installation.

Installation of Log Set and Embers:

is noticed call your dealer, distributor or courier company and have components replaced.

2.Ensure the temperature sensor will touch the unit when mounted. If it does not touch, adjust the sensor so it does.

2.Place the fan assembly behind the unit and secure with the three screws provided, (as shown in Figure 53).

3.Open the gas valve cover. Carefully cut the decal portion on the control panel and install the fan control switch in this location. See Figure 46 for wiring of optional blower.

4.Plug the fan assembly into the wall outlet and turn the unit on to ensure fan operation.

The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner come with four (4) locator pins, and the right log has two (2) ledges which make alignment easier. Using the pictures provided, carefully set the logs in place.

NOTE: The logs are fragile and should be handled gently.

CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. The use of other foreign materials on the burners may create dangerous conditions.

If over time, through cleaning and servicing, these embers require replacement, contact the nearest ENVIRO dealer for replacement embers.

Figure 54: Step 1 of Log Placement.

Figure 55: Step 2 of Log Placement.

34

Page 34