Enviro C-11290, C-10381 owner manual Initial Installation, Qualified Installers Only, Termination

Models: C-10381 C-11290

1 48
Download 48 pages 53.55 Kb
Page 21
Image 21
NOTES:

Initial Installation

QUALIFIED INSTALLERS ONLY

wall, run a bead of non-hardening mastic around the edges, so as to make a seal between the termination and the wall. The arrow on the vent termination should be pointing up, insure that the proper clearances to combustible materials are maintained.

5.Before connecting the horizontal run of the vent pipe to the vent termination, slide the black decorative wall thimble cover over the vent pipe.

6.Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the cap assembly. It is important that the vent pipe extend into the vent cap a sufficient distance with a minimum of 1¼” (3.2cm) overlap. Secure the connection between the vent cap pipe and the vent cap by attaching the two sheet metal straps extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the straps to the vent pipe. Bend any remaining portion of the sheet metal straps back towards the vent cap, so the decorative wall thimble will conceal it (see left image in Figure 27).

7.Slide the decorative wall thimble up to the wall surface and attach with the screws provided. Apply decorative brass or chrome trim if desired (see right image in Figure 27).

NOTES:

(a)The four (4) wood screws provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or other types of siding.

(b)For buildings with vinyl siding, a vinyl siding standoff, should be installed between the vent cap and the exterior wall (see Figure 28). Attach the vinyl siding standoff to the horizontal termination. The vinyl siding standoff prevents excessive heat from possibly melting the vinyl siding material. Note that the horizontal vent termination bolts onto the flat portion of the vinyl siding standoff (shaded area in Figure 28), so that an air space will exist between the wall and the vent termination.

(c)The horizontal run of vent pipe must be level and should have a ¼ inch rise for every one foot of run towards the termination. Never allow the vent to run downward. This could cause high temperature and may present the possibility of a fire.

(d)The location of the horizontal vent termination on the exterior wall must not be easily blocked or

obstructed. Refer to Initial Installation - Vent Configurations and Restrictor Settings.

(e)When installing a vent pipe in a chase the minimum clearance to combustibles is 2” (51 mm).

(f)Maintain manufacturer’s clearances to combustibles with venting.

Figure 28: Installing Vent Cap with Vinyl Siding

Figure 29: Installing Horizontal Vent

Stand-Off.

Termination.

21

Page 21
Image 21
Enviro C-11290, C-10381 owner manual Initial Installation, Qualified Installers Only, Termination