Enviro C-10381, C-11290 owner manual Maintenance And Service, Convert the pilot injector

Models: C-10381 C-11290

1 48
Download 48 pages 53.55 Kb
Page 12
Image 12
6. Convert the pilot injector:
Figure 13. Ignitor
assembly beside the
burner.
Figure 12: O-ring on valve screw.

Maintenance And Service

6. Convert the pilot injector:

 

 

 

 

 

 

 

 

 

 

 

 

a) Pull the pilot hood straight up to access

 

 

 

 

 

 

the pilot injector.

 

 

 

 

 

 

b) Using a 5/32” or 4 mm Allen key,

 

 

 

 

 

 

remove the pilot injector.

 

 

 

 

 

 

c) Install the new pilot injector supplied

 

 

 

 

 

 

with this conversion kit. Simply screw

 

 

 

 

 

 

the new injector inside the pilot hood

 

 

 

 

 

 

using the Allen key,

 

 

 

 

 

 

d) Reinstall the hood by placing the hood

 

 

 

 

 

 

on the assembly, line up the key way,

 

 

 

 

 

 

and snap into place.

 

 

 

 

 

 

 

Figure 9:

 

 

 

 

7. Convert the SIT gas valve:

Removing valve

 

 

 

 

a) Remove the black protection cap from

 

cap.

 

 

 

 

 

 

 

Figure 10: Removing

Figure 11: Flip

the HI/LO knob by hand shown in Figure 9.

 

b) Insert a 5/32” or 4 mm Allen wrench into

 

 

 

valve screw.

valve screw.

 

 

 

 

 

 

the hexagonal key-way of the screw (see

 

 

 

 

 

 

Figure 10), rotate it counter-clockwise

 

 

 

 

 

 

until it is free and extract it.

 

 

 

 

 

 

c)Check that the screw is clean and if necessary remove dirt.

d)Flip the screw (refer to Figure 11).

e)Using the Allen wrench as shown in

Figure 10, rotate the screw clockwise

until a torque of 9 inch lbs. WARNING! Do not over tighten the screw. It is recommended that you grip the wrench by the short side.

f)Verify that if the conversion is from NG to LPG, the screw must be re- assembled with the red o-ring visible (refer to Figure 12). If the conversion is from LPG to NG, the red o-ring of the screw must be not visible.

g)Re-attach the black protection cap that was removed in step a (Figure 9).

8.Reinstall the burner, brick panels, log set, embers, and glass door. Also refer

to Secondary Installation - Log Set and Embers Installation. When re-installing the

burner, ensure that the burner to pilot hood relationship is similar to what is shown in Figure 13. On some units you will need to pay special attention when installing the burner that the venturi adjustment rod is properly installed into the venturi adjustment piece welded to the burner venturi tube

9.Reconnect the main gas line if it was disconnected and open the shut-off valve at the gas line to the unit.

10.Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN TESTING FOR LEAKS.

11.Reconnect the electrical power to the unit.

12.Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and operation and proper flame appearance. Also refer to Secondary Installation - Log Set and Embers Installation for a flame appearance picture.

13.MAKE SURE that the conversion label is installed on or close to the rating label to signify that the unit has been converted to a different fuel type.

12

Page 12
Image 12
Enviro C-10381, C-11290 owner manual Maintenance And Service, Convert the pilot injector