Enviro C-10381, C-11290 Corner Installation, Initial Installation, Qualified Installers Only

Models: C-10381 C-11290

1 48
Download 48 pages 53.55 Kb
Page 28
Image 28
CORNER INSTALLATION:

Initial Installation

QUALIFIED INSTALLERS ONLY

Installation of Top Vented; Horizontal Termination:

This is the most common type of installation style. Set the unit in place.

Install a minimum 24” (61 cm) vertical chimney.

Install a 90° elbow, and mark the exterior wall where the vent would pass through.

Cut a 10” (25.4 cm) minimum hole in the wall to maintain clearances to combustibles around vent pipe. Frame hole if as shown in Figure 26.

Install wall thimble.

Install interior finished collar

Install the vent section through the wall and then install the vent termination.

Seal around the termination using a non hardening mastic.

CORNER INSTALLATION:

This type of installation can be used in a corner installation. If a 90° elbow is used in the horizontal plane, 36” (91.4 cm) must be subtracted from the allowable horizontal run shown in Figure 23.

Installation of Top Vented; Vertical Termination:

Termination

Inside

finished collar

Wall thimble

Vent pipe

Drywall

Exterior wall

Siding

Figure 43: Installation for Top Vented; Horizontal Termination.

Place the unit in place.

Drop a plumb bob from the ceiling to the center point of the flue outlet.

Cut a 10” (25.4 cm) hole in the ceiling and the roof. Refer to Figure 30.

Install the ceiling support and insulation guard.

Install the roof flashing. Ensure that the roof flashing is installed under the roofing material so that a watertight seal is created.

Install the flue pipe from the top of the unit through the roof.

Ensure that all flue pipe and unit maintain required clearances to combustibles.

CORNER INSTALLATION:

This type of installation can be used in a corner installation. If a 90° elbow is used in the horizontal plane, 36” (91.4 cm) must be subtracted from the allowable horizontal run shown in Figure 23.

Vent cap

Roof flashing Manual background

Roof

truss

Insulation

gaurd

Ceiling

support

Inside

finished collar

Flue pipe

Figure 44: Installation for Top Vented;

Vertical Termination.

28

Page 28
Image 28
Enviro C-10381, C-11290 owner manual Corner Installation, Initial Installation, Qualified Installers Only