SPINDLE SANDER TABLE

DISCONNECT MACHINE FROM POWER SOURCE.

1.The table (A) Fig. 43, can be moved up or down.

2.Loosen ratchet handle (C) Fig. 43, move table (A) to desired position and tighten handle (C).

3.The table can also be positioned on the oscillating belt by removing the table insert, and sliding the table down around the oscillating belt. Replace the table insert with the 4" table insert (D) Fig. 44, when using the sander table on the oscillating belt.

FENCE

DISCONNECT MACHINE FROM POWER SOURCE.

1.Loosen fence knobs (A) and (B) Fig. 45.

2.Move fence to desired position and tighten knobs (A) and (B) Fig. 45.

MITER GAGE

1.

The miter gage is equipped with adjustable index

stops at 90 degrees and 45 degrees right and left.

Adjustment to the index stops can be made by loosening

nuts (F) Fig. 46, and tightening or loosening the three

adjusting screws (B).

2.

To rotate the miter gage, loosen handle (A) Fig. 46,

flip the stop link (D) down and out of the way, and move

the body of the miter gage (C), to the desired angle.

A

C

Fig. 43

D

Fig. 44

AB

Fig. 45

3. The miter gage body (C) can stop at 90 degrees and

45 degrees both right and left by flipping the stop link

down and out of the way and moving the miter gage

body (C) past the 90 and 45 degree marks and flipping

the stop link (D) back up so that the stop link (D) will be

able to contact the adjusting screws (B) at the desired 90

A

F

B

C

or 45 degree angle. To rotate the miter gage body past

these points, the stop link (D) Fig. 46, must be down and

out of the way.

D F B F B

Fig. 46

18

Page 18
Image 18
Epson 31-396 instruction manual Spindle Sander Table, Miter Gage