8.3 Pipeline-following signals
Every coprocessor in the system must contain a pipeline follower to track the instructions
executing in the ARM720T processor pipeline. The coprocessors connect to the ARM720T
processor input data bus, EXTCPDOUT[31:0], over which instructions are fetched, and to
HCLK and EXTCPCLKEN.
It is essential that the two pipelines remain in step at all times. When designing a pipeline
follower for a coprocessor, you must observe the following rules:
•At reset (HRESETn LOW), the pipeline must either be marked as in valid, or filled
with instructions that do not decode to valid instructions for that coprocessor.
The coprocessor state must only change when EXTCPCLKEN is HIGH (except for
reset).
An instruction must be loaded into the pipeline on the rising edge of HCLK, and
only when CPnOPC, CPnMREQ, and CPTBIT were

all

LOW in the previous bus
cycle.
These conditions indicate that this cycle is an ARM state opcode Fetch, so the new
opcode must be sampled into the pipeline.
The pipeline must be advanced on the rising edge of HCLK when CPnOPC,
CPnMREQ, and CPTBIT are all LOW in the current bus cycle.
These conditions indicate that the current instruction is about to complete
execution, because the first action of any instruction performing an instruction
fetch is to refill the pipeline.
Any instructions that are flushed from the ARM720T processor pipeline never signal on
CPnCPI that they have entered Execute, so they are automatically flushed from the
coprocessor pipeline by the prefetches required to refill the pipeline.
There are no coprocessor instructions in the Thumb instruction set, so coprocessors must
monitor the state of the CPTBIT sig nal t o ensure that the y do not try to decode pairs of Thumb