9: Debugging Your System
9-22 EPSON ARM720T CORE CPU MANUAL
9.14 Test data registers
The six test data registers that can connect between DBGTDI and DBGTDO are described in
the following sections:

Bypass register

ARM720T processor device identification (ID) code register

Instruction register

on page 9-23

Scan path select register

on page 9-23

Scan chain 1

on page 9-17

Scan chain 2

on page 9-17.
In the following descriptions, data is shifted during every HCLK cycle when DBGTCKEN
enable is HIGH.

9.14.1 Bypass register

Purpose Bypasses the device during scan testing by providing a path
between DBGTDI and DBGTDO.
Length 1 bit.
Operating mode When the BYPASS instruction is the current instruction in the
instruction register, serial data is transferred from DBGTDI to
DBGTDO in the SHIFT-DR state with a delay of one HCLK cycle
enabled by DBGTCKEN.
There is no parallel output from the bypass register.
A logic 0 is loaded from the parallel input of the bypass register in
the CAPTURE-DR state.

9.14.2 ARM720T processor device identification (ID) code register

Purpose Reads the 32-bit device identification code. No programmable
supplementary identification code is provided.
Length 32 bits. The format of the ID code register is as shown in
Figure 9-9.
Figure 9-9 ID code register format
The default device identification code is 0x7f1f0f0f.
Operating mode When the IDCODE instruction is current, the ID register is
selected as the serial path between DBGTDI and DBGTDO.
There is no parallel output from the ID register.
The 32-bit device identification code is loaded into the ID register
from its parallel inputs during the CAPTURE-DR state.
011112272831
Version Part number Manufacturer identity 1