Configuring the printer

SSelf Test

S PRINT TEST 1 (see Chapter 1.8 Print Tests) S PRINT TEST 2 (see Chapter 1.8 Print Tests)

S PRINT TEST 3 gives information about technical releases and is intended

for service purposes only. Among other information, the page counter identifies the number of pages printed.

S I/F Test This function is used to test the serial interface. It enables test data to be sent out from the printer and returned by means of a closed loop connector plugged into the serial interface connector. The test data uses consist of PRINT

TEST 1.

SHex Dump

This function makes it possible that the data received by the printer can be analyzed. Control codes are no longer carried out, instead all data is printed in hexadecimal format and as ASCII characters. Any non-printable characters, such as carriage return are only represented as a single dot (.) in the ASCII list.

It may happen that the transmission of data to the printer will be interrupted during Hex Dump. In this case, printing of data received after the break is started on the next available line. The result is an irregular right margin which is not an indicator for any loss of data.

3-23