Sub Menu Function
Direction You can set from the following according to the way the projector is set up. s p.68
Normal, Pointing Up, Pointing Down
Operation Direct Power On: You can set whether or not (On/Off) to enable Direct Power On.
Be careful when this item is set to On because this unit turns on at the time of power recovery with this unit plugged-in to an outlet.
Sleep Mode: When set to On, this automatically stops projection when no image signal is being input and no operations are carried
out.
Sleep Mode Timer: When Sleep Mode is set to On, you can set the time before the projector automatically turns off within a range
of 1 to 30 minutes.
Shutter Timer: When set to On, this turns off the power automatically 120 minutes after the electric shutter is closed. Shutter
Timer is set to On at the time of purchase.
High Altitude Mode: Set to On when using the projector above an altitude of 1500 m.
BNC Sync Termination: Set the termination for the signal from the BNC input port. This should usually be set to Off. Set to On
when analog (75Ω) termination such as for switchers is necessary.
Remote Control Type: You can select Normal or Simple depending on the type of remote control.
Set this item to Normal to use the remote control provided with the projector. When Simple is selected, you can use the remote
control provided with other Epson projectors to operate this projector (except for EB-G5350/G5200W/G5100). This is useful if you
want to use a remote control that you are already familiar with to operate the projector.
However, you cannot use the remote control provided with the projector if this is set to Simple. Make sure you want to change this
setting to Simple because, if the projector is mounted on the ceiling or somewhere hard to reach, changing it back may be difficult.
Standby Mode You can use the functions that monitor and control the status of the projector over the network even when the projector is in
standby mode if this is set to Communication On.
You can use SNMP
g
to monitor and control the status of the projector over the network, or by using the EasyMP Monitor software
supplied with this product.
Cln. Air Filter Notice You can set whether or not (On/Off) to enable Cln. Air Filter Notice. When this is set to On and a clog in the air filter is
detected, the message is displayed on the screen.
Projector ID Set the ID within a range of 1 to 9. Off indicates that no ID is set. s p.30
Multi-screen When this is set to On, you can adjust the hue and brightness of images projected from a row of the several projectors.s p.32
Adjustment Level: You can adjust from black to white in five stages called Level 1 to 5, and in each of these 5 levels you can
adjust Brightness Correct. and Color Correct.
Brightness Correct.: Corrects the difference in the brightness of each projector.
Color Correct. (G/R) / Color Correct. (B/Y): You can correct the difference in the color of each projector.
When Multi-screen is set to On, Auto Iris does not work.
Language You can set the Language for message displays.
List of Functions
47