List of ESC/VP21 Commands

User’s Guide

156

Command List

When a power on command is sent to the projector, the power will turn on and the projector will change to warm-up mode. When the power has turned on, a colon ":" (3Ah) will be returned.

When the projector executes a command, it returns a ":" and waits for the next command to be sent.

If command processing terminates with an error, the projector outputs an error message and then returns the ":" code.

 

Item

Command

Power ON/OFF

ON

PWR ON

 

 

OFF

PWR OFF

 

 

 

 

 

Computer

SOURCE 10

 

 

 

 

DVIg

SOURCE 30

 

 

 

Signal selection

Video

SOURCE 41

 

 

S-Video

SOURCE 42

 

 

 

 

 

BNC

SOURCE B0

 

 

 

 

EasyMP (EMP-7950 only)

SOURCE 50

 

 

 

A/V Mute ON/OFF

ON

MUTE ON

 

 

OFF

MUTE OFF

 

 

 

 

 

Black

MSEL 00

 

 

 

A/V Mute Selection

Blue

MSEL 01

 

 

 

 

User's Logo

MSEL 02

 

 

 

Communication Protocol

Standard baud rate

: 9600 bps

Data length

: 8 bits

Parity

: None

Stop bit

: 1 bit

Flow control

: None

Connector shape

: D-Sub 9-pin (male)

Projector input port

: Control (RS-232C)

*When issuing any of the above commands, tack a Carriage Return (CR) code (0Dh) on to the end.