Epson EPL-6200L service manual Electrical Features, Temperature and Humidity Conditions

Models: EPL-6200L EPL-6200

1 204
Download 204 pages 24.3 Kb
Page 30
Image 30

EPSON EPL-6200/EPL-6200L

Revision A

1.2.6Storage and Transport of the Printer Main Unit and Optional Products (Consumables Packaged)

†Temperature and Humidity Conditions

Table 1-30. Temperature and Humidity Conditions

 

Temperature

Humidity

Warranty Period

Others

 

 

(°C)

(%RH)

 

 

 

 

 

 

 

 

Normal

035

3085

18 months

 

Conditions

 

 

 

 

 

 

 

 

 

 

 

High temperature:

High humidity:

 

No condensation

Severe

35 40

8595

1/30 of

 

Conditions

Low temperature:

Low humidity:

warranty period.

 

 

-200

1030

 

 

 

 

 

 

 

†Transportation Barometric Pressure

61.3 ~ 101.3 kPa or more (460 ~ 760 mmHg)

†Dropping

No abnormalities according to JIS Z0200-1998 Level 1

†Vibration

„

Frequency:

5 ~ 100Hz (Sweep time: 10 minutes)

„

Acceleration:

1G

„Direction of application: 3 dimensional

„ Time of application:

60 minutes along each X, Y, Z axis,

 

180 minutes in total

1.2.7 Electrical Features

†Fast Transient / Bursts (AC Line Noise) IEC 61000-4-4 compliance

Voltage 1 k: no malfunction occurs such as defective image quality. 2 kV: no damage to parts allowed.

†Instantaneous Outages

DIP 100% (at rated current - 10%) one cycle. No effect on printing quality

†Resistance to Static Electricity (IEC 61000-4-2 compliance)

„Direct contact discharge: 4.5 kV

„Indirect contact discharge: 4.5 kV

„ Aerial discharge:

8.5 kV

NOTE: Even when electric discharge as mentioned above occurs, the printer shall keep operating normally without any trouble which affects the basic performance or which can lead to breakdown of the printer.

†Inrush Current: 50 A or less (0-peak)

†Insulation Resistance: 10 MΩ or more (at DC 500 V)

†Dielectric Strength

No break down during application of the voltages shown below for one minute.

 

 

Across primary and chassis

 

For 100 V models

AC 1000 V

 

 

 

 

For 110 to 127 V models

AC 1000 V

 

For 220 to 240 V models

AC 1500 V

 

 

 

† Leak Current

 

Intended Market

Leak Current

100 V (Japan)

0.25 mA or less

 

 

110 to 127 V models

3.5 mA or less

220 to 240 V models

3.5 mA or less

 

 

Product Description

Basic Specifications

30

Page 30
Image 30
Epson EPL-6200 Electrical Features, Temperature and Humidity Conditions, Temperature Humidity Warranty Period Others