EPSON | Revision A |
3.4.2 | Electrical Noise |
|
| |
|
| Table |
| |
|
|
|
|
|
Step | Action and Question | Yes | No | |
|
|
| ||
|
| Parts below can be the source of this error (Chapter 4 Disassembly and Assembly) | ||
|
| • Main Board Assy (C533/C534 Main) (p.146) |
|
|
|
| • Power Supply Unit (PU1) (p.151) |
|
|
|
| • Fuser Unit (p.152) |
|
|
|
| • High Voltage Unit (HV1) (p.151) |
|
|
|
| • Photoconductor Unit (p.135) |
|
|
|
| • Developer Cartridge (p.135) |
|
|
|
| • Paper Cassette Unit Control Board (p.162) |
|
|
|
| • Duplex Unit Control Board (p.163) |
|
|
|
|
|
|
|
|
| External noise |
|
|
|
| 1. Check to see if within 3 m from the printer there is |
|
|
|
| another electrical apparatus, such as a generator, |
|
|
1 |
| radio transmitter or an apparatus incorporating a |
| Problem |
| motor. | Go to Step 2 | ||
| solved | |||
| 2. Turn off the power to the electrical apparatus in | |||
|
|
|
| |
|
| question or move the printer to a position at least 6 |
|
|
|
| m distant from the apparatus. |
|
|
|
| ♦Does the problem with electrical noise still occur? |
|
|
|
| AC grounding |
| Ask the |
2 |
| Check the AC power connection. | Go to Step 3 | customer for |
| ♦Is the AC power cable connected and grounded | repair of the | ||
|
|
| AC power | |
|
| properly? |
| |
|
|
| connection. | |
|
|
|
| |
|
|
|
|
|
|
| Grounding screw |
| Install the |
3 |
| Check the grounding screw of the AC Inlet. | Go to Step 4 | grounding |
| ♦Is the cable grounded properly? | screw | ||
|
|
| properly. | |
|
|
|
| |
|
|
|
|
|
|
| Photoconductor Unit (Drum Cartridge)/Developer |
|
|
4 |
| Cartridge (toner cartridge) |
| Problem |
| Replace the Photoconductor Unit or Developer | Go to Step 5 | ||
| solved | |||
| Cartridge. | |||
|
|
|
| |
|
| ♦Does the problem with electrical noise still occur? |
|
|
|
|
|
|
|
Table
Step | Action and Question | Yes | No | |
|
|
|
| |
5 | Continuity of cables |
| Replace the | |
Check continuity of each cable. | Go to Step 6 | defective | ||
| ♦Does each cable have continuity? |
| cable. | |
|
|
| ||
6 | Grounding of circuit boards |
| Ensure | |
Check grounding of circuit boards. | Go to Step 7 | |||
grounding. | ||||
♦Is grounding ensured? | ||||
|
|
| ||
|
|
|
| |
7 | Fuser unit |
| Replace the | |
Replace the fuser unit. | Go to Step8 | |||
fuser unit. | ||||
♦Does the problem still occur? | ||||
|
|
| ||
8 | High voltage unit |
| Replace the | |
Replace the high voltage unit. | Go to Step9 | high voltage | ||
| ♦Does the problem still occur? |
| unit. | |
|
|
| ||
|
|
|
| |
9 | Power supply unit |
| Replace the | |
Replace the power supply unit. | Go to Step10 | |||
power supply | ||||
| ♦Does the problem still occur? |
| unit. | |
|
|
| ||
10 | Main Board Assy. | Replace all | Problem | |
Replace the Main Board Assy. | ||||
the relevant | ||||
solved | ||||
| ♦Does the problem still occur? | parts. |
| |
|
|
| ||
|
|
|
|
Troubleshooting | Troubleshooting for Abnormal Operations | 120 |