DC2

Cancel Condensed/Elite/Proportional

Format:

DC2

ASCII code:

Decimal:

18

Hexadecimal:

12

Comments:

Cancels condensed, elite, and proportional printing and selects pica printing. The command does not cancel double-wide.

ESC [@

 

Select Double-high Printing (FX-286e)

Format:

ESC

[

@ n1

n2

m1

m2

m3

m4

ASCII code:

Decimal:

27

91

64

n1

n2

m1

m2

m3

m4

Hexadecimal:

1B

5B

40

n1

n2

m1

m2

m3

m4

Comments:

The following values must be used: nl = 4, n2 = 0, ml = 0, and m2 = 0. The value of m3 affects both character height and line feed as shown below:

m3

Char heightLine feed

1

Standard

Unchanged

2

Double-high

Unchanged

16

Unchanged

Single

17

Standard

Single

18

Double-high

Single

32

Unchanged

Double

33

Standard

Double

34

Double-high

Double

 

 

 

The value of m4 selects the width of the characters.

1:Standard

2:Double-wide

A - 4 2

Command Summary