Epson RP-U420 manual Paper sensor commands ESC c, C O N F I D E N T I A L, Ver. 1.0 p

Models: RP-U420

1 77
Download 77 pages 19.06 Kb
Page 49
Image 49
Paper sensor commands ESC c 3

C O N F I D E N T I A L

ESC c 3

SETTING COMMAND

[Name]

Select paper sensor(s) to output paper-end signals

[Format]

ASCII

ESC

c

3

n

 

Hex

1B

63

33

n

 

Decimal

27

99

51

n

[Range]

[Default]

[Description]

0 n 255

n= 0

Selects the paper sensor(s) to output paper-end signals

Each bit of n is used as follows:

Bit

Off/On

Hex

Decimal

Function

 

 

 

 

 

0

Off

00

0

Journal near-end sensor disabled

 

 

 

 

 

 

On

01

1

Journal near-end sensor enabled

 

 

 

 

 

1

Off

00

0

Receipt near-end sensor disabled

 

 

 

 

 

 

On

02

2

Receipt near-end sensor enabled

 

 

 

 

 

2-7

Off

00

0

Reserved

 

 

 

 

 

[Notes]

The command is available only with a parallel interface and is ignored with a serial interface.

 

When all the sensors are disabled, the paper-end signal always outputs a paper present status.

Program Example

PRINT #1, CHR$(&H1B);"c3";CHR$(1); Journal near-end sensor enabled