C O N F I D E N T I A L
ESC c 5
SETTING COMMAND
[Name] | Enable/disable panel buttons |
|
| ||
[Format] | ASCII | ESC | c | 5 | n |
| Hex | 1B | 63 | 35 | n |
| Decimal | 27 | 99 | 53 | n |
[Range] | 0 ≤ n ≤ 255 |
|
|
|
|
[Default] | n = 0 |
|
|
|
|
[Description] | Enables or disables the receipt/journal feed buttons. |
•When the Least Significant Bit (LSB) of n is 0, the receipt/journal feed buttons are enabled
•When the LSB of n is 1, the receipt/journal feed buttons are disabled
[Notes]■ Only the LSB of n is valid.
■ When the receipt/journal feed buttons are disabled, no buttons on the receipt/journal feed are usable, except in the following case:
• Receipt/journal feed buttons are enabled when the cover is opened
Program Example
PRINT #1, CHR$(&H1B);"c5";CHR$(1); ← Disable panel buttons
Panel button command ESC c 5 | Ver. 1.0 p. 51 |