C O N F I D E N T I A L
DLE DC4
■■ ■■ ■■ moremore
EXECUTING COMMAND
[Name]
[Format]
[Range]
[Default]
[Description]
Generate pulse at |
|
|
| |||
ASCII | DLE | DC4 | n | m | t | |
Hex | 10 | 14 | n | m | t | |
Decimal | 16 | 20 | n | m | t | |
n = 1 |
|
|
|
|
| |
0 | ≤ m ≤ 1 |
|
|
|
|
|
1 | ≤ t ≤ 8 |
|
|
|
|
|
None
Outputs the pulse specified by t to connector pin m as follows:
mFunction
0Drawer
1Drawer
| • | The pulse ON time is [t × 100] ms, and the OFF time is [t × 100] ms. |
[Notes] | ■ | The printer executes this command upon receiving this command. |
| ■ | This comand cannot be executed when the unrecoverable error occurs. |
■ With a serial interface model, this command is executed even when the printer is offline, the receive buffer is full, or there is an error status.
■ With a parallel interface model, the printer cannot receive data when it is busy; therefore this command cannot be used under the following conditions.
• When DIP Switch
• When DIP Switch
■ This command is executed any time the data sequence <10>H<14>H<n><m> <0> is received, even if it appears as part of another command.
<Example>
In ESC * m nL nH d1 ... dk, d1=<10>H, d2=<14>H, d3=<1>,d4=<0>, d5=<5>
Miscellaneous commands DLE DC4 | Ver. 1.0 p. 76 |