SED1520 Series

Read-Modify-Write

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W

 

 

 

 

 

 

 

 

 

 

 

A0

 

RD

 

WR

D7

D6

D5

D4

D3

D2

D1

D0

 

 

0

1

 

0

 

1

1

1

0

0

0

0

0

E0H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This command defeats column address register auto-increment after data reads. The current conetents of the column address register are saved. This mode remains active until an End command is received.

• Operation sequence during cursor display

When the End command is entered, the column address is returned to the one used during input of Read-Modify-Write command. This function can reduce the load of MPU when data change is repeated at a specific display area (such as cursor blinking).

*Any command other than Data Read or Write can be used in the Read-Modify-Write mode. However, the Column Address Set command cannot be used.

Set Page Address

Set Column Address

Read-Modify-Write

Dummy Read

Read Data

Write Data

No

Completed?

Yes

End

End

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W

 

 

 

 

 

 

 

 

 

A0

 

RD

 

WR

D7

D6

D5

D4

D3

D2

D1

D0

 

0

1

 

0

 

1

1

1

0

1

1

1

0

EEH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This command cancels read-modify-write mode and restores the contents of the column address register to their value prior to the receipt of the Read-Modify-Write command.

Return

Column address

N

N+1 N+2 N+3

N+m

N

 

Read-Modify-Write mode is selected.

 

End

2–18

EPSON