SED1520 Series
AC Characteristics
• MPU Bus Read/Write I
A0,CS |
|
|
t AW8 | t CC | t AH8 |
WR,RD |
| t r |
|
|
tCYC8
tf
t DH8
tDS8
D0 to D7 (WRITE)
t OH8
tACC8
D0 to D7
(READ)
Ta =
|
| Parameter | Symbol | Condition | Rating | Unit |
| Signal | ||||||
|
| Min. | Max. |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Address hold time | tAH8 |
| 10 | — | ns |
|
|
|
|
|
|
| |
|
| A0, CS | ||||||||||||
|
|
|
|
|
|
|
|
| ||||||
| Address setup time | tAW8 |
| 20 | — | ns | ||||||||
|
|
|
|
|
|
|
|
| ||||||
| System cycle time | tCYC8 |
| 1000 | — | ns |
|
|
|
|
|
|
| |
|
| WR, RD | ||||||||||||
| Control pulsewidth | tCC |
| 200 | — | ns |
| |||||||
|
|
|
|
|
|
|
|
| ||||||
| Data setup time | tDS8 |
| 80 | — | ns |
|
|
|
|
|
|
| |
| Data hold time | tDH8 |
| 10 | — | ns | D0 to D7 | |||||||
|
|
|
|
| — | 90 | ns | |||||||
| RD access time | tACC8 | CL = 100 pF | |||||||||||
|
|
|
|
|
|
|
| |||||||
| Output disable time | tCH8 | 10 | 60 | ns |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||||||
| Rise and fall time | tr, tf | — | — | 15 | ns |
| — |
(VSS =
|
| Parameter | Symbol | Condition | Rating | Unit |
| Signal | |||||||
|
| Min. | Max. |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Address hold time | tAH8 |
| 20 | — | ns |
|
|
|
|
|
|
| |||
— |
| A0, CS | |||||||||||||
Address setup time | tAW8 | 40 | — | ns |
| ||||||||||
|
|
|
|
|
|
|
| ||||||||
System cycle time | tCYC8 |
| 2000 | — | ns |
|
|
|
|
|
|
| |||
— |
| WR, RD | |||||||||||||
Control pulse width | tCC | 400 | — | ns |
| ||||||||||
|
|
|
|
|
|
|
| ||||||||
Data setup time | tDS8 | — | 160 | — | ns |
|
|
|
|
|
|
| |||
Data hold time | tDH8 | 20 | — | ns | D0 to D7 | ||||||||||
| |||||||||||||||
|
|
|
|
| — | 180 | ns | ||||||||
RD access time | tACC8 | CL = 100 pF | |||||||||||||
|
|
|
|
|
|
| |||||||||
Output disable time | tCH8 | 20 | 120 | ns |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||||||||
Rise and fall time | tr, tf | — | — | 15 | ns |
| — |
SED1520 | Series |
|
|
EPSON |