SED1520 Series

AC Characteristics

• MPU Bus Read/Write I (80-family MPU)

A0,CS

 

 

t AW8

t CC

t AH8

WR,RD

 

t r

 

 

tCYC8

tf

t DH8

tDS8

D0 to D7 (WRITE)

t OH8

tACC8

D0 to D7

(READ)

Ta = –20 to 75 deg. C, VSS = –5.0 V±10% unless stated otherwise

 

 

Parameter

Symbol

Condition

Rating

Unit

 

Signal

 

 

Min.

Max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address hold time

tAH8

 

10

ns

 

 

 

 

 

 

 

 

 

A0, CS

 

 

 

 

 

 

 

 

 

 

Address setup time

tAW8

 

20

ns

 

 

 

 

 

 

 

 

 

 

System cycle time

tCYC8

 

1000

ns

 

 

 

 

 

 

 

 

 

WR, RD

 

Control pulsewidth

tCC

 

200

ns

 

 

 

 

 

 

 

 

 

 

 

Data setup time

tDS8

 

80

ns

 

 

 

 

 

 

 

 

Data hold time

tDH8

 

10

ns

D0 to D7

 

 

 

 

 

90

ns

 

RD access time

tACC8

CL = 100 pF

 

 

 

 

 

 

 

 

 

Output disable time

tCH8

10

60

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rise and fall time

tr, tf

15

ns

 

(VSS = –2.7 to –4.5 V, Ta = –20 to +75°C)

 

 

Parameter

Symbol

Condition

Rating

Unit

 

Signal

 

 

Min.

Max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address hold time

tAH8

 

20

ns

 

 

 

 

 

 

 

 

A0, CS

Address setup time

tAW8

40

ns

 

 

 

 

 

 

 

 

 

System cycle time

tCYC8

 

2000

ns

 

 

 

 

 

 

 

 

WR, RD

Control pulse width

tCC

400

ns

 

 

 

 

 

 

 

 

 

Data setup time

tDS8

160

ns

 

 

 

 

 

 

 

Data hold time

tDH8

20

ns

D0 to D7

 

 

 

 

 

 

180

ns

RD access time

tACC8

CL = 100 pF

 

 

 

 

 

 

 

Output disable time

tCH8

20

120

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rise and fall time

tr, tf

15

ns

 

SED1520

Series

 

 

EPSON

2–23