SED1520 Series

• MPU Bus Read/Write II (68-family MPU)

t CYC6

 

E

 

 

t EW

t r

t f

t AW6

t DS6

R/W

 

 

t AH6

A0,CS

 

 

t DH6

D0 to D7

 

(WRITE)

 

t ACC6

t OH6

D0 to D7

 

(READ)

 

Ta = –20 to 75 deg. C, VSS = –5 V±10 unless stated otherwise

Parameter

Symbol

Condition

Rating

Unit

Signal

Min.

Max.

 

 

 

 

 

 

 

 

 

 

 

 

System cycle time

tCYC6

 

1000

ns

 

 

 

 

 

Address setup time

tAW6

 

20

ns

A0,

CS,

R/W

 

Address hold time

tAH6

 

10

ns

 

 

 

 

 

Data setup time

tDS6

 

80

ns

 

 

 

 

 

Data hold time

 

tDH6

 

10

ns

D0 to D7

Output disable time

tOH6

 

CL = 100 pF

10

60

ns

 

 

 

 

 

Access time

 

tACC6

90

ns

 

 

 

 

 

 

 

 

 

 

 

 

Enable

 

Read

tEW

 

 

100

ns

 

E

pulsewidth

 

Write

 

 

80

ns

 

 

 

 

 

 

 

 

 

 

Rise and fall time

tr, tf

15

ns

 

(VSS = –2.7 to – 4.5 V, Ta = –20 to +75°C)

Parameter

Symbol

Condition

Rating

Unit

Signal

Min.

Max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System cycle time*1

tCYC6

2000

ns

 

 

 

 

 

Address setup time

tAW6

 

 

40

ns

A0,

 

 

 

 

 

CS,

R/W

 

Address hold time

tAH6

 

20

ns

 

 

 

 

 

 

 

 

 

 

 

 

Data setup time

tDS6

 

160

ns

 

 

 

 

 

Data hold time

 

tDH6

 

20

ns

D0 to D7

 

 

 

Output disable time

tOH6

CL = 100 pF

20

120

ns

 

 

 

 

 

Access time

 

tACC6

180

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

 

Read

tEW

 

200

ns

 

E

pulse width

 

Write

 

160

ns

 

 

 

 

 

 

 

 

 

 

 

 

Rise and fall time

tr, tf

15

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: 1. tCYC6 is the cycle time of CS. E = H, not the cycle time of E.

2–24