SED1520 Series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W

 

 

 

 

 

 

 

 

 

 

 

A0

 

RD

 

WR

D7

D6

D5

D4

D3

D2

D1

D0

 

 

0

1

 

0

 

1

1

1

0

0

0

1

0

E2H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This command clears

the display start line register.

and set page address register to 3 page.

It does not affect the contents of the display data RAM.

When the power supply is turned on, a Reset signal is entered in the RES pin. The Reset command cannot be used instead of this Reset signal.

Power Save (Combination command)

The Power Save mode is selected if the static drive is turned ON when the display is OFF. The current consumption can be reduced to almost the static current level. In the Power Save mode:

(a)The LCD drive is stopped, and the segment and common driver outputs are set to the VDD level.

(b)The external oscillation clock input is inhibited, and the OSC2 is set to the floating mode.

(c)The display and operation modes are kept.

The Power Save mode is released when the display is turned ON or when the static drive is turned OFF. If the LCD drive voltage is supplied from an external resistance divider circuit, the current passing through this resistor must be cut by the Power Save signal.

VDD VDD

V1

V2

SED1520

V3SED1522

V4

V5

Power Save signal

VSSH

If the LCD drive power is generated by resistance division, the resistance and capacitance are determined by the LCD panel size. After the panel size has been determined, reduce the resistance to the level where the display quality is not affected and reduce the power consumption using the divider resistor.