1.2.5 Electrical SpecificationsTable 1-8. Rated Electrical Ranges
Specification 120 V Version 220 - 240 V Version
Ratedvol tage 120 VAC 220 - 240VAC
Inputvoltage range 103.5 ∼
132 V
198 ∼
264 V
Ratedfreque ncy range 50 ∼
60 Hz
50 ∼
60 Hz
Inputfrequenc y range 49.5 ∼
60.5 Hz
49.5 ∼
60.5 Hz
Ratedcurrent 0.5 A 0.3 A
Powerconsumption Approx. 15 W
(self-test with 10-cpi LQ characters) Approx. 15 W
(self-test with 10-cpi LQ characters)
Insulationresistance 10 MΩ,
minimum
(applying 500 VDCbetween AC
line and chassis)
10 MΩ
, minimum
(applying 500 VDC between AC line
and chassis)
Dielectric strength 1000 VAC rms for 1 minuteor
1200 VACrms for 1 second
(between AC line andchassis)
1500 VACrms for 1 minute
(between ACline and chassis)
1.2.6 Environmental ConditionsTable 1-9. Acceptable Environmental ConditionsCondition Operating Non Operating
Temperature 10 ∼
35
°
C (50
∼
95
°
F)
*1
−
20
∼
60
°
C (
−
4
∼
122
°
F)
*2
Humidity 20 ∼
80% RH
*1,3
5∼
85% RH
*2,3
Shock resistance 1G (within 1 msec.) 2G (within 2 msec.)
*2
Vibration resistance 0.15 G 0.50 G
*2
*1 :For printer operation, conditions must be in the range shown in the figure below.
*2
: Theseconditions are applicable when the printer is in its shipping container.
*3
: Without condensation.
80%
55%
20%
Humidity
(% RH) Guaranteed Range
(Degrees)
10 27 35
Figure 1-5. Temperature/Humidity of Range
Epson Stylus Color200 /Epson Stylus 200 Product Description
Rev. A 1-7