3.2.6.9 Cap Unit Removal
1. Remove the printermec hanism(see Section 3.2.5).
2. Remove the front frame(see Section 3.2.6.6).
3. Remove 1 CPS (M3x6) screw securingthe cap unit to the lower frame.
4. Remove 1 CPS (M3x6) screw securingthe black holde r to theframe
5. Remove the whitetube conne ctingthe cap unit to the pump unit.(Be careful an ink leak when you
remove this inktube.)
6. Remove 3 screws — 1CPS (M3x6), 1 CPS (M3x12), and 1 CPS (M3x8) — securing the pump unit to
themain frame.
7. Release a tension spring securingthe paper pick up trigger holder to the pump mechanism.
Notes:
1. When you remove the pump unit, be sure to keep the washer, located behind the pump.
2. When you remove the pump unit, do not lose the pin in the pin holder.
White Tube
CPS(M3x6)
1
CPS(M3x6)
CPS(M3x6)
Black Holder
CPS(M3x12)
CPS(M3x8)
Hexagonal Screw
Tension Spring
Shift
2Push
Figure 3-19. Pump Unit ReleasingEPSON Stylus Color 200 / EPSON Stylus 200 Disassembly and Assembly
Rev. A 3-13