In the Table 2-1, if the control sequence is executed in incremental order, the carriage motor rotates
clockwise (CW). (The CR moves from 1stcolumn to 80th column.)
Signals output from ports P105, P106, and P107 of the CPU determine the reference trip current level
used by the motor driver IC for drive current control. Table 2-2 lists the connection of the output
signalsand the referenc e trip current levels.
Table 2-2. Connection between References and Output Signals
Reference
(TripCurre nt) P105 P106 P107 Duty Change
601 mA OFF OFF OFF 1, 2/3, 1/3, 0
481 mA ON OFF OFF As above
444 mA OFF ON OFF As above
403 mA OFF OFF ON As above
375 mA ON ON OFF As above
345 mA ON OFF ON As above
326 mA OFF ON ON As above
110 mA OFF ON ON Fixed to 1/3

EPSON Stylus COLOR 200 / EPSON Stylus 200 Operating Principles

Rev. A 2-3