3.2.6.10 Paper Feed Motor Removal

1. Remove the printermechanism (see Section 3.2.5).
2. Remove the pumpunit. (see Section 3.2.6.9).
3. Remove the 2 CBB(M3x10) screws securing the paper feed motor to the motor frame.
Pin
HOLE
Pin Holder
Pump Unit
Pin
Figure 3-20. Pin Position
PF Motor
CBB(M3x10)
CBB(M3x10)
Pump Unit
Figure 3-21. Paper Feed Motor Removal
Disassembly and Assembly EPSON Stylus Color 200 / EPSON Stylus 200
3-14 Rev. A