Exabyte EXB-8505 8mm manual Air Flow Requirements, Particulate Contamination Limits

Models: EXB-8505 8mm

1 124
Download 124 pages 49.85 Kb
Page 109
Image 109

6 Functional Specifications

Air Flow Requirements

Adequate air flow must be provided in the enclosure for the tape drive to dissipate heat resulting from approximately 15.0 watts of power consumption. The air flow around the entire tape drive must be sufficient to prevent the tape path temperature from exceeding 40° C (104° F). However, air flow within the enclosure must be minimal at the tape path. Otherwise, particulate contamination of the media can result.

Particulate Contamination Limits

The ambient operating environment should not exceed the particulate counts shown in Table 6-11.

Table 6-11Particle contamination limits

Particle

Number of Particles

Number of Particles

Size

Particle Size per Cubic

Particle Size per Cubic

(microns)

Meter

Foot

 

 

 

 

 

 

0.1

8.8

107

2.5

106

0.5

3.5

107

1.0

106

5.0

2.5

105

7.0

103

Figure 6-4shows the particulate contamination profile of a typical office compared to the specifications for the tape drive. Contamination profiles of individual office areas vary.

May 1994

EXB-8205 and EXB-8505

6-17

 

(Standard and XL)

 

Page 109
Image 109
Exabyte EXB-8505 8mm manual Air Flow Requirements, Particulate Contamination Limits, 11Particle contamination limits