6Functional Specifications
Figure 6-4 Particulate contamination specification vs. typical office
Shock Specifications
Table
Table 6-12 Shock specifications
Operating | Storagea or Not Operatingb | Transportationa |
3 g for 5 msc | 45 g at a velocity change of | NSTA Project 1A |
| 192 inch/secd |
|
aThe tape drive has not been unpacked.
bThe tape drive has been unpacked, but no power has been applied.
cA minimum of 20 shock pulses were applied to each of the three orthogonal axes. The shock pulses were
dA minimum of three trapezoidal shock pulses of 45 g were applied to each of the tape drive’s six sides at a velocity change of 192 inches per second (equivalent height equals 48 inches).
510504 | ||
| (Standard and XL) |
|