G0084

CAUTION

POTENTIAL HAZARD

Operating a mower deck with loose or weakened blade bolts can be dangerous.

WHAT CAN HAPPEN

A loose or weakened blade bolt could allow a blade rotating at a high speed to come out from under the deck, causing serious injury or property damage.

HOW TO AVOID THE HAZARD

Replace the blade bolt after striking a foreign object. (Use only Exmark replacement parts PN 103-0862 – blade bolt and PN 103-0865 – spring disk washer).

DO NOT lubricate the threads of the bolt or spindle before assembly.

Torque the blade bolt to 115-120 ft-lbs. (156-163 N-m).

G0084

FIGURE 8

BLADE BOLT INSTALLATION

5.1.7Check safety interlock system.

Service Interval: Daily

a)Check starting circuit. Starter should crank with, parking brake engaged, PTO disengaged and motion control levers moved out in the neutral lock position. The operator does not need to be in the seat to start the engine.

Try to start with operator in seat, parking brake disengaged, PTO disengaged and motion control levers in the neutral lock position - starter must not crank.

Try to start with operator in seat, parking brake engaged, PTO engaged and motion control levers in the neutral lock position - starter must not crank.

Try to start with operator in seat, parking brake engaged, PTO disengaged, and the left motion control lever in, starter must not crank, repeat again with the right lever in, then with both levers in - starter must not crank.

b)Check the kill circuits. Run engine at one-third throttle, disengage parking brake and raise off of seat (but do not get off of machine) engine must stop after approx. 1/2 second has elapsed (seat has time delay kill switch to prevent cut-outs on rough terrain).

Run engine at one-third throttle, engage PTO and raise off of seat (but do not get off of machine) engine must stop after 1/2 second has elapsed.