Symptoms/Cause

 

Remedy

 

 

 

Link LED on LEX unit is

1.

Disconnect all USB devices from the REX

on;

 

 

unit.

Host LED on LEX unit

2.

Disconnect the LEX unit from the computer.

is off.

3.

Disconnect and then reconnect the power

Cause:

 

adapters to the WiRanger.

a)

The computer is not

4.

Reconnect the LEX unit to the computer.

 

functioning.

5.

In the Universal Serial Bus controllers section

b)

The LEX unit is not

 

of Device Manager, check that the WiRanger

 

connected to the

 

is recognised as a “Generic USB Hub”.

 

computer.

6.

If the problem persists, move the LEX unit and

c) There is too much

 

REX unit together so that they are about 1

 

Radio Interference

 

meter apart (3’) and power both units and

 

for USB

 

connect the LEX unit to the host PC.

 

communication to

7.

Confirm that the WiRanger can establish a

 

succeed.

 

 

radio link and that the Host LED’s turn on.

d)

The WiRanger is

 

8.

If the WiRanger is still not recognised, contact

 

malfunctioning.

 

 

Technical Support for assistance (see page

 

 

 

20).

A device is connected

1.

Disconnect the WiRanger from the computer.

to REX unit and the

2.

Connect the USB device directly to the USB

corresponding Device

 

port on the computer.

LED is off

 

3.

If the device does not operate properly,

Cause:

 

consult the user documentation for the device.

a)

The USB device is

4.

If the device operates properly when directly

 

malfunctioning.

 

 

connected to the computer, connect another

b)

The computer does

 

device (of a different type) to the WiRanger.

 

not recognise the

 

Connect the WiRanger to the computer.

 

USB device.

5.

If the second device does not operate, the

c)

The application

 

WiRanger may be malfunctioning. Contact

 

software for the

 

Technical Support for assistance (see page

 

device is not

 

20).

 

operating.

6.

If the second device does operate properly,

d)

The WiRanger is

 

the first device may not be compatible with the

 

malfunctioning.

 

WiRanger. Contact Technical Support for

 

 

 

assistance (see page 20).