Changing the Baud Rate

The RS-232 protocol factory setting is 9600 baud, 8-bits, no parity, 1 start bit and 1 stop bit. The position of internal rotary switch SW3 on the main controller board controls the baud rate and parity. To change the switch setting, remove the four screws from the top of the case and lift the cover straight up. Locate SW3 (see drawing below) and use a small, flat blade screwdriver to rotate the switch to the desired position. SW3 switch positions are defined in the table below.

8-bit, no parity, 1 stop bit

0 = 300 baud

1 = 600 baud

2 = 1200 baud

3 = 2400 baud

4 = 4800 baud

5 = 9600 baud

6 = 19200 baud

7 = 38400 baud

8-bit, odd parity, 1 stop bit

8 = 300 baud

9 = 600 baud A = 1200 baud B = 2400 baud C = 4800 baud D = 9600 baud E = 19200 baud F = 38400 baud

_ Adjust SW3 to set the RS-232 Baud Rate and Protocol.

SW3 Rotary Switch