Installation and Setup, cont’d
Operation
Power Input
1.Connect the captive screw connector from the supplied 12 VDC power supply into the power receptacle.
NThe FOX 2G Tx/Rx AV does not have a remote powering feature. Both the transmitter and the receiver require their own separate power supply.
POWER 12V
0.6A MAX
Power Receptacle
DC Power Cord
Captive Screw Connector
Negative +12 VDC
External
Power Supply
(12 VDC, 1 A )
AC Power Cord
Figure 2-8 — Connecting power
NThe length of the exposed wires in the stripping process is critical. The ideal length is 3/16” (5 mm). Any longer and the exposed wires may touch, causing a short circuit between them. Any shorter and the wires can be easily pulled out even if tightly fastened by the captive screws.
CDo not tin the wires. Tinned wire does not hold its shape and can become loose over time.
2. Connect the AC power cord of the power supply unit to a 110 or 220 VAC electrical source.