Maintenance and Modifications
The most probable corrective maintenance procedures for your HSA 200 or HSA 222 are leveling the top surface and replacing the gas lifts. Most of the maintenance procedures require removing the surface mount enclosure from the table.
Removing and Replacing the Enclosure
•The procedure for replacing the bezel in an HSA 222 only requires removing the HSA from the table.
•The procedure for replacing the gas lift requires removing the HSA 200 or HSA 222.
•The procedure for levelling the top surface may require removing the HSA.
Remove and replace the surface mount enclosure for maintenance as follows:
Ensure that AC power is disconnected before servicing the HSA unit.
1. Disconnect:
•The IEC power cord
•The
•(HSA 200 models only) Any device plugged into the AC power outlet
•(HSA 200 models only) The BNC (video) connectors
•(HSA 200 models only) The audio connector
•(HSA 200CE and HSA 200SE only) The power supply connector
|
| The surfaces of the HSA enclosure have screws and other | |
|
| protrusions that could damage fine furniture. Do not | |
|
| rest the enclosure on unprotected furniture. | |
5. | Perform the desired maintenance procedure. | ||
6. | If the surface is not level, adjust the top surface. See | ||
| “Adjusting the Top Panel” in this chapter. | ||
7. | Carefully lower the HSA enclosure into the table opening. | ||
8. | From the underside of the table, reinstall the screw clamps | ||
| on the enclosure at a height at which the clamp will reach | ||
| the underside of the tabletop. | ||
9. | Snugly tighten the Philips head screws on the screw | ||
| clamps to secure the enclosure to the surface. | ||
|
| Overtightening the Philips head screws on the screw | |
| CAUTION | ||
|
|
| clamps can bend the clamp’s horizontal flange. |
10. Tighten the locking thumbscrews on the screw clamps to lock the clamp in position.
11. Reconnect all of the connectors removed in step 1.
Replacing the Bezels
The HSA ships with
To change to a different color connector bezel or if a connector is not needed, replace the connector bezel
If no connector is desired, snap the
2. Loosen the locking thumbscrews on the screw clamps to unlock the clamp.
3. Loosen the screw clamps.
4. Remove the screw clamps on
both sides of the enclosure.
Lift the enclosure from the table.
Screw
Clamp
Thumbscrew
interior
Replace a bezel as follows:
1. (HSA 222 models only) Remove the surface mount enclosure from the table. See “Removing and Replacing the Enclosure”, steps 1 through 4.
CAUTION | The flanged edges of the top of the surface enclosure |
| are bevelled to an |
| 0.04 (4/100)” (approximately 1 mm), and are |
| therefore very sharp. These edges are also soft and |
| may be easily nicked or bent. Exercise caution |
| when handling and mounting the enclosure. |
| Mishandling may result in injury to the installer or |
| damage the appearance of the enclosure. |
HSA 200/222 Series • Maintenance and Modifications |