Preparing the Table and Mounting the Enclosure
The preferred and recommended method for preparing the table is to use the appropriate Extron routing template and a router. The templates are available at no cost; see the part numbers for the templates in appendix A, “Reference Information”.
For an HSA 200C, HSA 200CE, or HSA 222C unit (US version only), another preferred method is to use a 6" hole saw.
Alternatively, for any model, you can use a paper
CAUTION | The opening in the table for the HSA enclosure |
| should be cut only by licensed and bonded |
| craftspeople. Exercise care to prevent scarring or |
| damaging the furniture. |
| The routing templates for the various HSA models |
| are not interchangeable. If you use the wrong |
| template, you will cut an |
| you use a larger template than required, the cut will |
| result in gaps in the table surface on either side of |
| the enclosure. |
| The surfaces of the HSA enclosure have screws and |
| other protruding hardware that could damage fine |
| furniture. Do not rest the enclosure on unprotected |
| furniture. |
Preparing the table with a router
1. | Locate the desired mounting location on the tabletop or | |
| other installation surface. Mark the location. | |
2. | Place the mounting template assembly on the table, | |
| centered on the mounting location. Angle the template for | |
| the optimum positioning. If necessary, use a square to | |
| ensure that the template is properly positioned. Extron is | |
| not responsible for | |
|
| Ensure that only the wooden strips contact the |
| CAUTION | |
|
| furniture. Failure to do so may mar the furniture. |
3. | Once the template assembly is positioned properly, secure | |
| the assembly to the table with clamps (figure |
Figure 2-2 — Cutting the opening with a router (example)
4. | Using a router with a 5/8" (or 16 mm) outside diameter | |||
| guide bushing and a 1/2" (or 12 mm or 12.7 mm) | |||
| diameter straight router bit, carefully cut the opening in | |||
| the table surface (figure | |||
|
|
|
| Wear safety glasses when operating the router. |
|
|
|
| |
|
|
|
| Failure to comply can result in eye injury. |
5. | Remove the clamps and the routing template. |
The routing template is reusable. Do not discard the template when the installation is complete. Save it to install other HSA products of the same size.
HSA 200/222 Series • Installation | HSA 200/222 Series • Installation |