Extron electronic HSA 200S Installation, cont’d Preparing the Table and Mounting the Enclosure

Models: HSA 200SE HSA 200S HSA 222C

1 30
Download 30 pages 34.8 Kb
Page 10
Image 10
Installation, cont’d

Installation, cont’d

Preparing the Table and Mounting the Enclosure

The preferred and recommended method for preparing the table is to use the appropriate Extron routing template and a router. The templates are available at no cost; see the part numbers for the templates in appendix A, “Reference Information”.

For an HSA 200C, HSA 200CE, or HSA 222C unit (US version only), another preferred method is to use a 6" hole saw.

Alternatively, for any model, you can use a paper cut-out template (see a ppendix A, “Reference Information”) and a sabre saw or keyhole saw, but this method is not recommended.

CAUTION

The opening in the table for the HSA enclosure

 

should be cut only by licensed and bonded

 

craftspeople. Exercise care to prevent scarring or

 

damaging the furniture.

 

The routing templates for the various HSA models

 

are not interchangeable. If you use the wrong

 

template, you will cut an improperly-sized hole. If

 

you use a larger template than required, the cut will

 

result in gaps in the table surface on either side of

 

the enclosure.

 

The surfaces of the HSA enclosure have screws and

 

other protruding hardware that could damage fine

 

furniture. Do not rest the enclosure on unprotected

 

furniture.

Preparing the table with a router

1.

Locate the desired mounting location on the tabletop or

 

other installation surface. Mark the location.

2.

Place the mounting template assembly on the table,

 

centered on the mounting location. Angle the template for

 

the optimum positioning. If necessary, use a square to

 

ensure that the template is properly positioned. Extron is

 

not responsible for improperly-positioned HSA products.

 

 

Ensure that only the wooden strips contact the

 

CAUTION

 

 

furniture. Failure to do so may mar the furniture.

3.

Once the template assembly is positioned properly, secure

 

the assembly to the table with clamps (figure 2-2).

Figure 2-2 — Cutting the opening with a router (example)

4.

Using a router with a 5/8" (or 16 mm) outside diameter

 

guide bushing and a 1/2" (or 12 mm or 12.7 mm)

 

diameter straight router bit, carefully cut the opening in

 

the table surface (figure 2-2).

 

 

 

 

Wear safety glasses when operating the router.

 

 

 

 

 

 

 

 

Failure to comply can result in eye injury.

5.

Remove the clamps and the routing template.

The routing template is reusable. Do not discard the template when the installation is complete. Save it to install other HSA products of the same size.