4-15ISS 408 Integration Seamless Switcher • Programmer’s Guide

Command ASCII Command Response Additional description
(host to switcher) (switcher to host)
Set ISS name (location) Esc X30 CN Ipn• X30
Read ISS name (location) EscCN X30
Set GMT/date Esc X31CT Ipt• X32
The date and time entered should be Greenwich Mean Time (GMT).
Read GMT/date EscCT X32
Set IP address Esc X33CI Ipi• X33 The switcher sends the response,
but the host may not receive it.
Read IP address Esc CI X33
Read hardware address EscCH X35
Read # of open connections EscCC X36
Set administrator password Esc X34 CA Ipa• X34
Read administrator password EscCA X34
Set user password EscX34CU Ipu• X34
Read user password EscCU X34
When the computer is connected to the switcher via the RS-232 link, the Admin and User password
fields are not masked. If a password has been inadvertently changed to an unknown value, you can
look up and, if desired, change a password in this window without knowing the current password.
Command/response table for IP SIS commands
X30 = ISS name (Up to 240 characters)
X31 = GMT Time and date (set) MM/DD/YY-HH:MM:SS, where
MM = month: 01 (January) through 12 (December)
DD = day: 01 through 31
YY = year: 00 through 99
HH = hour: 00 through 23
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X32 = Time and date (read) In the format: Day,•DD•MMM•YYYY•HH:MM:SS GMT, where
Day = weekday: Mon through Sun
DD = day: 01 through 31
MM = month: Jan through Dec
YYYY = year: 2000 through 2099
HH = hour: 00 through 23
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X33 = IP address ###.###.###.###
X34 = Password 12 digits, alphanumeric
X35 = Hardware address ##-##-##-##-##-##
X36 = Number of open connections 0 - 255