Extron electronic MC104 IP setup guide Hardware Setup, cont’d, Power wiring

Models: MC104 MC104 IP

1 23
Download 23 pages 31.53 Kb
Page 10
Image 10

Hardware Setup, cont’d

D

MLS RS-232 port — This port can control an optional Extron

 

switcher or other RS‑232 controllable device.

 

If you connect an optional switcher (such as an Extron

 

MLS Series switcher) to the MLC, you must connect a ground

 

wire between the switcher and the MLC, as shown in the

 

following diagram.

NPower the controller via an external power supply, not from an Extron switcher. The controller requires a separate 12 VDC power supply.

NCheck the power supply’s polarity before connecting it to the MLC. See the diagram below.

MLC/IR

MediaLink

A B C

Switcher's

 

 

rear panel

 

MLC/IR port

 

NOTE You must connect a

 

ground wire

 

between the MLC

 

and MLS.

Smooth Ridges

A

A

SECTION A–A

 

 

Power Supply

 

Output Cord

Power wiring

GROUND +12V IN

PWR

12V

0.2” (5 mm) MAX.

MLC's

Power

Port

 

Ground ( )

 

 

 

B Receive (Rx)

Transmit (Tx)B

 

 

A Transmit (Tx)

Receive (Rx)A

 

 

 

Rx Tx

 

 

 

A B

 

 

 

GROUND

 

 

MLS

 

 

RS-232

 

 

MLC 104 Series

 

 

Right Side Panel

 

N For a list of Extron switchers this connector supports, refer

 

to the MLC 104 Series User's Manual.

E

PWR (power) connector — To provide power to the MLC,

 

connect a cable between this port and a 12 VDC, 1 amp

(maximum) power supply, as shown below. For power wiring instructions, see the diagram on the following page.

Ground ( ) +12 VDC input

An external

power supply

F

LAN connector and LEDs (IP model only) — An Ethernet

 

connection can be used on an ongoing basis to control the

 

MLC 104 IP (and the devices connected to it) in an Ethernet

 

network.

 

Use a straight-through cable for connection to a switch,

 

 

hub, or router.

 

Use a crossover cable for connection directly to a PC.

 

Configure the settings for this port via either SIS commands, an

 

embedded Web page, or Global Configurator.

 

LAN port defaults are as follows:

 

IP address: 192.168.254.254

 

gateway IP address: 0.0.0.0

 

subnet mask: 255.255.0.0

 

DHCP: off

GROUND +12V IN

PWR

12V

MLC 104 Series Right Side Panel

Ground all devices.

(12 VDC, 1 A max.)

Connecting an MLC 104 Series controller to an external power supply

2-4

MLC 104 Series MediaLink Controllers • Hardware Setup

MLC 104 Series MediaLink Controllers • Hardware Setup

2-5