NDo not tin the stripped power supply leads before installing the captive screw connector. Tinned wires are not as secure in the captive screw connectors and could pull out.
WThe two power cord wires must be kept separate while the power supply is plugged in. Remove power before continuing.
Audio output (line level)
b Phantom power switch — Provides switchable 48 volt phantom power for condenser microphones.
c Line Output — A
3/16"
(5 mm) MAX
Captive Screw
Connector stripping
Tip
Ring
Sleeve
CAUTION
For unbalanced audio, connect the sleeve(s) to the ground. DO NOT connect the sleeve(s) to the negative
Tip
NO Ground Here
Sleeve
d Low Cut filter switch — Provides low cut filtering to remove wind and “table rumble” noise.
Remote connection
e Remote — An optional