If the MP 101 will be installed without a wall box (using mud rings or fastening it directly to the wall or furniture), measure and mark the surface for the cutout area indicated in the template.

3.Cut out the material from the marked area.

4.Check the opening size by inserting the wall box (if used) or the MP 101 (if no box is used) into the opening. The box and preamplifier should fit easily into the opening. Enlarge or smooth the edges of the opening if needed.

5.Feed cables through the wall box punch-out holes, and secure them with cable clamps to provide strain relief.

6.Exposed cable shields (braids or foil) are potential sources of short circuits. Trim back and/or insulate shields with heat shrink.

Metal Wall Box

Screw

Cable Clamp

Manual background Braided Shield

Install Cable

Foil Shield

WTo prevent short circuits, cut back the outer foil shield to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable, as shown above.

7.Insert the wall box into the opening, and attach it to the wall, stud, or furniture.