installation information, refer to the installation guide shipped with the Decora faceplate.

Remote Control

Remote connector wiring

Pin 1 is 10 VDC reference voltage. Pin 2 is volume control DC voltage; range is 0 to 10 V, where 0 V is mute and 10 V provides maximum volume. Pin 3 is ground.

NAll nominal levels are at ±10%.

MAX

10K

MIN

REMOTE

1

2

3

10V

VOL/MUTE

1

2K

2

MUTE

3

GND

Remote control options

The MP 101 D has three remote control options:

1.The Extron VCM 100 volume/mute controller and

VC 50 volume controller use a 10 k ohm potentiometer as the main method for controlling volume levels.

The VCM 100 includes an illuminated Mute button and operates in sync with the MP 101 AAP.

2.The Extron MLA-VC10converts RS-232 serial command to 0~10 volt variable DC for volume control.

3.Generic volume/mute controllers are standard 10 k ohm potentiometers.

MP 101 Series • MP 101 D 4-7