Extron electronic MVX 88, MVX 44, MVX 84, 48 manual Remote Connection, RS-232 Port Pin Assignment

Models: 48 MVX 84 MVX 44 MVX 88

1 70
Download 70 pages 45.03 Kb
Page 12
Image 12
Remote Connection

Figure 5. RS-232 Port Pin Assignment NOTES: The length of exposed wires is critical. The ideal length is 3/16 inch (5 mm). Manual background

• If the stripped section of wire is longer than 3/16 inch, the exposed wires may touch, causing a short circuit.

If the stripped section of wire is shorter than 3/16 inch, wires can be easily pulled out even if tightly fastened by the captive screws.

• Figure 4 on the preceding page identifies the tip, ring, and sleeve. A mono audio connector consists of the tip and sleeve. A stereo audio connector consists of the tip, ring and sleeve. If you are wiring a captive screw connector from an existing unbalanced audio cable, the white insulated wire is typically the left channel (tip) and the red insulated wire is typically the right channel (sleeve). There is no reliable standard for existing balanced audio cables.

The audio level for each input can be individually set, via the front panel or RS-232, to ensure that the level on the output does not vary from input to input. See the “Operation” section and the “Remote Operation” section.

By default, the audio follows the video switch. Audio breakaway, which is commanded via the front panel, via RS-232 control using SIS commands or the Windows-based control program, or via optional IR 501 control, allows you to select from any one of the audio input sources. See the “Operation” section, the “Remote Operation” section, and the IR 501 Small Matrix IR Remote Control User Guide.

Remote Connection

dRS-232 connector — Connect a host device, such as a computer or control system, to the switcher via this 9-pin D connector (figure 5) for remote control of the switcher.

5 1

96 Female

Pin

RS-232

Function

1

Not used

2

TX

Transmit data (-)

3

RX

Receive data (+)

 

 

 

4

Not used

5

Gnd

Signal ground

6— Not used

7— Not used

8— Not used

9— Hardwired IR

Figure 5. RS-232 Port Pin Assignment

Manual background NOTE: The cable used to connect the RS-232 port to a computer or control

system may need to be modified by removing pins or cutting wires. If you encounter problems while operating under RS-232 control (the switcher

may hang up), pins 1, 4, 6, 7, and 8 may need to be disconnected. Either

cut the wire to pins 1, 4, and 6 through 8 in a hard-shelled connector or remove pins 1, 4, and 6 through 8 from a molded plug.

See the “Remote Operation” section for definitions of the SIS commands and details on how to install and use the control software.

Using the hardwired IR input on pin 9, you can use a control system with IR-learning capabilities to operate the switcher just as if you were using an IR 501 remote control. The control system must first “learn” the IR command from an IR 501, after which it sends the same commands to the MVX via pin 9.